Description
1. Description
The ES631-G2 Cable Discharge Event (CDE) Evaluation System is a comprehensive solution designed to simulate the effects of charged cable (Ethernet, USB, HDMI, etc…) discharge to any system or device.
The system is designed with three CDE test modes (single line discharge mode, differential pair discharge mode, contact sequence discharge mode) and two Failure/Degrade Inspection Connections (Oscilloscopes or Link Partner Paths). Therefore, it allows user to be able to setup, simulate and analyze the cable discharge event in all different discharge combinations. This system also allows traffic tester to connect through the CDE test system to check the traffic functionality.
LABVIEW control software is an option provided for customers for full functions in remote control. The system is also designed with a versatile 5-inch large touchscreen interface for panel operation.
2. Features
- Ethernet Cable ESD test up to 4.0 kV
- Multiple CDE test modes available
(Single Line Discharge, Differential Pair Discharge, Contact Sequence Discharge) - Dual Failure/Degrade Inspection Modes
(Oscilloscope Link Pulse Test or Link Partner Traffic Test) - Embedded ESD current probes for discharged lines
- 5 Inch Large Touch Screen Control
- USB-Optical RS232 (virtual serial port) remote control
- Firmware upgrade-able
- Multiple Cable Adapters available (USB, HDMI, Ethernet, etc.…)
- Powerful LABVIEW ATE Software (automatic test control)
3. Applications
- General Cable Discharge Event (CDE) and analysis
- PHY ESD protection test and analysis
- Network switch / router ESD robustness test and analysis
- Automatic Test Equipment (ATE) for system level Cable ESD
4. Specifications
CDE Main Controller Base Unit
Model | ES631-G2.2 | ES631-G2.4 |
Maximum Charge voltage | ± 2 kV | ± 4 kV |
Charge voltage Resolution | 10 V Step | 10 V Step |
Charge voltage stability | ± 0.1% per hour (after 30 min warm up) | |
Number of charge lines | 8 lines ( 4 differential pairs ) | |
Number of current probes | 8 probes for 4 differential pairs | |
Current Probe Specification | SMA connectors, 1V/A, from 1.2 KHz -200 MHz, Precision ± 3% | |
DUT Connection Port | Unshielded RJ45 | |
DUT Connection Port | Shielded RJ45 | |
Charge Cable Unit Connection Port | ESDEMC Designed High Voltage 9 Pin Circular Connector | |
Dimension | 35 x 28 x 15 cm (17.5 x 13 x 5.9 inch) | |
Weight | About 10 kg (22 lb) |
Options for ES631-G2 CDE Main Controller
Option Number | Descriptions |
ES631-AUSB3 | ES613 Charge Cable Adapter for USB |
ES631-PUSB3 | ES613 DUT Probe for USB |
ES631-ARJ45 | ES613 Charge Cable Adapter for RJ45 |
ES631-PRJ45 | ES613 DUT Probe for RJ45 |
ES631-AHDMI | ES613 Charge Cable Adapter for HDMI |
ES631-PHDMI | ES613 DUT Probe for HDMI |
ES631-LAN-SW | LABVIEW Software for ATE test control |
ES631-LAN-CAL | ES631 CDE System Discharge Waveform Calibration Setup |
Ethernet Charge Cable Module
Model | ES631-LAN-C5EUTP200
200 meter CAT5E UTP |
ES631-LAN-C5EFTP200
200 meter CAT5E FTP |
Maximum voltage from line to GND | DC High Voltage Break Down Tested up to ± 4.5 kV | |
Maximum voltage Between Lines | DC High Voltage Break Down Tested up to ± 4.5 kV | |
Cable Length | 200 ± 2 Meter | |
Ethernet Cable Type | CAT 5 Unshielded Twisted Pair | CAT5 Shielded Twisted Pair |
Dimension | 35 x 28 x 15 cm (17.5 x 13 x 5.9 inch) |
35 x 28 x 15 cm (17.5 x 13 x 5.9 inch) |
Weight | About 23 kg, ( 50 lb ) | About 19 kg, ( 40 lb ) |
5. Ordering Information
Line | Part or Option Number | Description |
1 | ES631-G2.2 | ES631-G2.2 CDE Main Controller, 2kV Base Unit |
2 | ES631-G2.4 | ES631-G2.4 CDE Main Controller, 4kV Base Unit |
3 | ES631-AUSB3 | ES613 Charge Cable Adapter for USB |
4 | ES631-PUSB3 | ES613 DUT Probe for USB |
5 | ES631-ARJ45 | ES613 Charge Cable Adapter for RJ45 |
6 | ES631-PRJ45 | ES613 DUT Probe for RJ45 |
7 | ES631-AHDMI | ES613 Charge Cable Adapter for HDMI |
8 | ES631-PHDMI | ES613 DUT Probe for HDMI |
9 | ES631-SW | LABVIEW Software for ATE test control Option for ES631-LAN CDE System |
10 | ES631-CAL | Discharge Waveform Calibration Option for ES631-LAN CDE System |
11 | ES631-LAN-C5EUTP200 | 200 meter CAT5E UTP Charge Cable Module |
12 | ES631-LAN-C5EFTP200 | 200 meter CAT5E FTP Charge Cable Module |