A4001 ESD Current Target Calibration Kit (DC-4 GHz, 30 kV)

A4001 ESD Current Target Calibration Kit (designed by the original designer of the ESD Current Target in standard committee, David Pommerenke), is a wide-band ESD Target for ESD simulators calibration according to the latest IEC 61000-4-2 and ISO 10605 standards. The wide-band attenuator provides return loss and the cable is used as the connection to the oscilloscope. The frequency response specifications are taken with the complete assembly.

$3,500$4,000

Add to quote

Description

It is well known that the old 1GHz current target described in previous editions of IEC 61000-4-2 had limitations that prevented the user from seeing high frequency ringing and noise that might exists. Now that higher bandwidth oscilloscopes are now readily available, the improved 4 GHz ESD current calibration kit becomes necessary – otherwise measurements are still limited by the older target design.

A4001 ESD Current Target Calibration Kit (designed by the original designer of the ESD Current Target in standard committee, David Pommerenke) is a DC-4 GHz wide-band ESD Target for ESD simulators calibration according to the latest IEC 61000-4-2 and ISO 10605 standards. The attenuator provides return loss and the cable is used as the connection to the oscilloscope. The frequency response specifications are taken with the complete assembly.

A4001 ESD Current Target Calibration Kit is comparable to Haefely PET 4000, Teseq MD 103, Noiseken 06-00067A, and EM Test CTR2.

ESDEMC has been the ESD Current Target supplier for Haefely Hipotronics, Thermo Fisher Scientific, ESDGuns.com, etc…

Applications:

ESD Current Measurement

ESD Simulator Discharge Current Calibration

 A4001-Kit-N-20+6 Specifications:

ESD Target Surface Finish Gold Plated, never oxidized or rusted
Measurement Bandwidth DC – 4 GHz
< ± 0.5 dB up to 1GHz
< ± 1.2 dB up to 4GHz
Input Resistance 2.08 Ohm (± 1%)
(2.00 Ohm in parallel with 50 Ohm load)
Max. IEC Pulse Level Tested up to ± 30kV
Voltage Non-linearity <2% up to ± 20 kV
< 5% up to ± 30kV
Coaxial Cable Type  RG400, Double Shielded
Coaxial Cable Length 0.8 m
Coaxial Cable Connector SMA – N Type
 Transfer impedance 5A/V with default 20dB attenuator
Meets Standards IEC 61000-4-2 ED. 2.0 B:2008
ISO 10605:2008

Default Configuration:

A4001-N Gold Plated Wide-band ESD Target with N Type Connector
AT2WN-20 N Type Attenuator, DC-18 GHz, 2W , 20 dB
RG4-NS-8 RG400 Coaxial Cable, N-SMA Connectors, 0.8 meter
A4001-SMA2BNC High Precision SMA-BNC Adapter
A4001-CAL NIST Traceable Factory Calibration Report

Optional Accessories:

A4001-SMA Gold Plated Wide-band ESD Target with SMA Connector
AT2WN-6 N Type Attenuator, DC-18 GHz, 2W, 6 dB
(Use in addition with 20 dB ATT for up to 30 kV calibration)
AT2WN-30  N Type Attenuator, DC-18 GHz, 2W, 30 dB
(Use instead of default 20 dB ATT for up to 30 kV ESD calibration)
AT2WS-20 SMA Type Attenuator, DC-18 GHz, 2W, 20 dB
RG4-SS-8 RG400 Coaxial Cable, SMA-SMA Connectors, 0.8 meter
A4001-Repair ESD target repair (will work with other brands ESD Targets)
A4001-ReCal Re-Calibration of ESD Target (NIST Traceable)
A4001-TP ESD Current Calibration Shielding Plane
A4001-TSC ESD Current Calibration Shielding Cabinet with EMI Filter

 

Additional information

Weight 1 kg
Dimensions 45 × 30 × 15 cm
ESD Target Connector

N Type Connector, SMA Connector

Attenuator Value

20 dB, 30 dB, 20 + 6 dB

Impedance

1 Ohm, 2 Ohm

Documents

A4001 ESD Current Target Calibration Kit Datasheet

TN002 ESD Current Target Calibration Method

TN003 ESD Simulator Calibration Method (IEC61000-4-2 & ISO10605)