Description
1.Description
ESDEMC’s EM602-10 is a 10 GHz Mini TEM Cell generates a very strong electromagnetic field for testing small devices such as sensors, IC’s, wireless communication modules, etc. An external test signal applied through the input port of the TEM cell generates a consistent and predictable TEM test field inside the cell. The radiation field from a device transmitting in the cell can also be detected through the port using a test receiver.
The unique compact design is optimized for a very strong electromagnetic field injection test beyond the standard TEM Cell in both field strength and frequency range. The E-H field inside the test volume is proportional to the input voltage and inversely proportional to the cell height. If a radiating object is inserted inside the cell, the radiated wave toward the input port is guided by the transmission line and picked up at the input with a receiver such as a spectrum analyzer. With this method, the RFI from a radiating device can be measured quantitatively. Since this apparatus is very broadband, it has many applications in the area of EMI, EMS, receiver sensitivity test, etc. The EM602 TEM Cell requires 40W input power to achieve > 20 kV/m RMS E-field or > 80 A/m RMS H-field. It is recommended that the test PCB have metal-plated edges for better shielding.
2.Features:
- Up to 10 GHz bandwidth (Beyond normal TEM Cell bandwidth of 3 GHz)
- Can inject up to 20 km/m E-field for sensor EM Field Susceptibility
3.Applications:
- Electromagnetic immunity test of IC
- Electromagnetic radiation test of IC
- ESD Field susceptibility test of IC
- IEC 61967-2:2005 Integrated circuits – Measurement of electromagnetic emissions, 150 kHz to 1 GHz – Part 2: Measurement of radiated emissions – TEM cell and wideband TEM cell method
- IEC 61967-8:2011 Integrated circuits – Measurement of electromagnetic emissions, 150 kHz up to 3 GHz – Part 8: Measurement of radiated emissions – IC stripline method
- IEC 62132-8:2012 Integrated circuits – Measurement of electromagnetic immunity, 150 kHz up to 3 GHz – Part 8: Measurement of radiated immunity – IC stripline method
- SAE 1752-3 Measurement of Radiated Emissions from Integrated Circuits — TEM/Wideband TEM (GTEM) Cell Method; TEM Cell (150 kHz to 1 GHz), Wideband TEM Cell (150 kHz to 8 GHz)
4.Specifications:
Frequency range | DC – 10 GHz (First spike by undesired higher order mode > 10 GHz) |
TEM Cell Impedance | 50Ω ± 5% nominal |
VSWR | DC- 3 GHz <1.2 3 – 10 GHz <1.5 |
Insertion Loss (S21) | DC- 10 GHz <1 dB |
Return Loss (S11 & S22) | DC- 3 GHz >20 dB 3 – 10 GHz >14 dB |
Effective Cell Height | 1.6 mm |
E-Field Strength at Center of Cell | >= 20 kV/m @ 40W |
H-Field Strength at Center of Cell | >= or 80A/m @ 40W |
RF Connectors | SMA |
Maximum Input Power | 70 Watts |
Maximum Input Voltage | 1 kV |
Test PCB Dimensions | 26 x 26 mm |
Recommended MAX DUT Dimensions | 3.5(W) x 3.5(L) x 0.8(H) mm |
Weight | Approx 0.2 kg |