Description
1.Description
The CT-T16 series broadband current transformers are designed to monitor current pulse transients. The probe’s frequency response 3 dB bandwidth spans from 1 kHz to 300 MHz. The probe enclosure has a through-hole diameter of 15mm.
2.Features
- Flat transfer impedance at high frequencies
- Compact, lightweight, and robust design
- 15mm through-hole diameter
- SMA-connector measurement ports
3.Applications
- High frequency current measurement
- ESD and EOS pulse current measurement
4.Specifications
Parameter | Value |
Probe Factor (V/A) | 0.1 |
Transfer Impedance (dBΩ) | -20 |
Current-Time Product (A∙µs) | 200 |
Flat Response Bandwidth (3dB) | 1 kHz – 300 MHz |
5. Ordering Information
Line | Part # or Option # | Description | Status |
1 | CT-T16-0p1 | CT-T16 Broadband Current Transformer, 0.1 V/A | Active |