CT-C02 Broadband Current Transformer

The CT-C02 series broadband current transformers are designed to monitor current in both time domain and frequency domain measurement applications.  This clamping-style probe has a 32 mm inner diameter, a 71 mm outer diameter, and a draw-latch clamp.  The probe’s frequency response 3 dB bandwidth nominally spans from 100 kHz to 1 GHz.

Features

  • Flat transfer impedance
  • Compact, lightweight, and robust design
  • Spring-loaded draw-latch clamp
  • Outer Diameter of 71 mm
  • Inner Diameter of 32 mm
  • Type-N connector

Add to quote

Description

1.    Description

The CT-C02 series broadband current transformers are designed to monitor current in both time domain and frequency domain measurement applications. This clamping-style probe has an inner diameter of 32 mm, an outer diameter of 71 mm, and a draw-latch clamp. The probe’s frequency response 3 dB bandwidth nominally spans from 100 kHz to 1 GHz.

2.    Features

  • Flat transfer impedance
  • Compact, lightweight, and robust design
  • Spring-loaded draw-latch clamp
  • Outer Diameter of 71 mm
  • Inner Diameter of 32 mm
  • Type-N connector

3.    Applications

  • High frequency current measurements
  • Conducted emissions measurements

4.    Specifications

Parameter Value
Frequency Range (3 dB Bandwidth) 100 kHz – 1 GHz
Inner Diameter 32 mm
Outer Diameter 71 mm
Height 19 mm
Nominal Transfer Impedance 1 V/A
Nominal Transfer Impedance (dB) 0 dB
Connector Type Type-N
Max RMS Current 15 A

 

5.    Ordering Information

Line Part # or Option # Description Status
1 CT-C02 CT-T02 Broadband Current Transformer, 100 kHz – 1 GHz Active

Documents

CT-C02 Broadband Current Transformer DATASHEET (PDF)